Fire Detection & Suppression

Fire Detection & Suppression

Sectors: Oil & Gas ┬À Energy ┬À Manufacturing ┬À Data Centres ┬À Warehousing ┬À Pharmaceuticals

Fireworld Safety Systems provides the full spectrum of fire detection and suppression technologies. Every system is hydraulically calculated, engineered to BS EN or NFPA standards, and commissioned and certified by our qualified fire protection engineers.

VESDA / Aspirating Smoke Detection

Very Early Warning, Pre-Alarm Investigation Window

  • Detection sensitivity: 0.0015 %/m to 6.25 %/m obscuration
  • Sampling pipe network: up to 200m per detector head
  • Alarm levels: 4-level output (Alert / Action / Fire 1 / Fire 2)
  • Environment: -20C to +60C, 10-95% RH (non-condensing)
  • Certifications: EN 54-20, UL 268A, FM 3260
  • Suppliers: Xtralis VESDA-E, Wagner TITANUS, Siemens FDA
  • Applications: Data centres, server rooms, NOCs, switchgear rooms, clean rooms, warehouses

Addressable & Conventional Fire Detection

  • Smoke: Optical point, ionisation, beam, duct, multi-sensor detectors
  • Heat: Fixed temperature (57C, 78C, 90C), rate-of-rise, linear heat detection cable, thermal imaging
  • Manual call points: Standard break-glass, ATEX-rated Ex MCPs, weatherproof outdoor
  • Suppliers: Hochiki, Simplex (JCI), Siemens, FireTech
  • Standards: BS EN 54, NFPA 72, BS 5839

Automatic Sprinkler Systems

BS EN 12845 / NFPA 13, Hydraulically Calculated

  • Wet pipe: Standard occupied buildings
  • Dry pipe: Cold storage, unheated spaces
  • Pre-action: Sensitive equipment areas
  • Deluge: High-hazard process areas
  • ESFR: High-bay warehouse protection

Clean Agent Suppression

Total Flooding, Electrically Non-Conductive

  • FM-200 (HFC-227ea): Fast-acting clean agent
  • Novec 1230: Zero ODP, low GWP
  • CO2: Engine rooms, flammable liquid stores
  • IG-541 / IG-55: Inert gas systems
  • Standards: NFPA 2001 / BS EN 15004
  • Room integrity test (blower door) as standard

Foam Suppression Systems

AFFF / FFFP / AR-AFFF, Tank Farm & Bund Protection

  • Foam pourers and chamber systems for tank protection
  • Deluge foam-water systems for bund areas
  • 3% and 6% AFFF, alcohol-resistant AR-AFFF
  • Standards: NFPA 11 / BS EN 13565

Water Mist Systems

High-Pressure Mist, Turbine & Machinery Protection

  • EnviroMist high-pressure water mist
  • Gas turbine enclosure, machinery space, engine room systems
  • Standards: NFPA 750 / IMO MSC/Circ.1165
Fireworld Safety Systems - Contact our engineering team

Protect Your Facility. Protect Your People.

Whether you need a risk assessment, a new system, or ongoing maintenance, get in touch with our engineering team today.

Call WhatsApp Get a Quote