Sectors: Oil & Gas · Energy & Power · Pharma · Chemical · Data Centres · Manufacturing · Critical Infrastructure
Fireworld is a complete gas-systems integrator — from clean-agent manufacture and gaseous suppression design through to fixed and portable gas detection, with personal safety monitoring across the workforce. We are the only company in East Africa with in-house clean-agent gas refilling and an ISO-aligned calibration laboratory.
Gaseous Suppression Systems
Supply · Installation · Maintenance
- FM-200 (HFC-227ea) total-flooding systems for data centres, switchgear, archives
- Novec 1230 low-GWP clean-agent systems for environmentally-sensitive applications
- CO2 high-pressure systems for transformer rooms, paint booths, generator enclosures
- Inert gas (IG-541, IG-55, IG-100) systems for occupied spaces
- Local-application water-mist for kitchen hoods and machinery
- Full lifecycle: hazard analysis, hydraulic calculation, BS EN 15004 / NFPA 2001 design, installation, commissioning, room integrity testing, annual service contracts
- Cause-and-effect integration with fire detection and BMS
Clean Agent Gas Manufacture
In-House Refilling · East Africa’s Only Facility
- FM-200, Novec 1230, CO2, IG-541, IG-55 cylinder refilling at our Namanve facility
- Gravimetric filling to ±0.5% accuracy with traceable batch certification
- Cylinder receipt, weighing, pressure test, refill, certification and return-to-service
- On-site agent recovery and top-up at the client facility
- Eliminates overseas shipping delays — typical turnaround in days, not weeks
- Each refill ships with agent batch certificate, fill-weight record, and cylinder test certificate
Fixed Gas Detection Systems
Supply · Installation · Calibration
- Fixed-point detection: catalytic, infrared, electrochemical sensors for flammable, toxic, and oxygen-deficient atmospheres
- Open-path infrared detectors for perimeter and large-area coverage
- Acoustic gas leak detection for high-pressure facilities
- ATEX / IECEx Zone 0, 1, and 2 certified instruments
- Dräger PointGard, PIR 7000 / PIR 3000, REGARD 7000 control panels
- Detector placement studies (CFD-assisted) for high-value installations
- Routine and annual calibration to manufacturer specification, traceable to ISO 17025 reference gases
- Sensor replacement and lifecycle management programmes
Personal Safety Monitoring Devices
Supply · Maintenance · Fleet Management
- Single-gas personal monitors (H2S, CO, O2, LEL) for confined-space and high-risk work
- Multi-gas portable monitors (4-gas and 5-gas) — Dräger X-am 5100 / X-am 8000, MSA ALTAIR 4XR / 5X, Crowcon T4
- SCBA (self-contained breathing apparatus) supply, service, and air refill
- Docking stations and fleet management software for large user populations
- Bump-testing and calibration with traceable certification
- Hire fleet for short-duration projects, shutdowns, and turnarounds
- User training on operation, alarm response, and routine self-tests
Standards & Compliance
- BS EN 15004 / ISO 14520 — Clean-agent gaseous fire-extinguishing systems
- NFPA 2001 — Clean Agent Fire Extinguishing Systems
- BS EN 60079 / IEC 60079 — Hazardous-area equipment (ATEX / IECEx)
- BS EN 60079-29 / ISO 26142 — Performance requirements for gas detectors
- ISO 17025 — Traceable calibration reference standards